Structure

Main Functions
Overload
Underload
Short circuit
Blocking
Stall
Unbalance
Insulation Fault
OverVoltage
Undervoltage
Phase Failure
Phase Sequence
OverPower
tE time
Loss of pressure (anti-shake)
4-20mA input protection
Ground
Leakage
CE
3.Ccommunication
Modbsu-RTU
Modbus-TCP,
Profibus-DP
Profinet



Overload
Underload
Short circuit
Blocking
Stall
Unbalance
Insulation Fault
OverVoltage
Undervoltage
Phase Failure
Phase Sequence
OverPower
tE time
Loss of pressure (anti-shake)
4-20mA input protection
Ground
Leakage
CE
3.Ccommunication
Modbsu-RTU
Modbus-TCP,
Profibus-DP
Profinet



-
1) ARD2 Smart Motor Protector
● Suitable for motors with rated voltage of AC380V/660V;
● Optional leakage protection, RS485 communication, analog output, etc.
● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 4 channels DO output. -
2) ARD2F Smart Motor Protector
● Measurement functions are divided into basic measurement (current parameter) and co-selection measurement (voltage, power, phase sequence, residual current (leakage current);
● Start timeout, overload, stall, block, underload, phase failure, unbalance, residual current (ground/leakage), temperature, external fault, phase sequence, overvoltage, undervoltage, underpower, overpower, tE time Motor comprehensive protection function;
● 9-channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 5-channels DO output, which can meet the direct start, star-delta start, autotransformer start, soft start and other starting modes. Real-time remote control "start/stop" operation of the remote master station can be realized through the communication bus;
● It has standard RS485 communication interface and adopts Modbus-RTU and Profibus-DP communication protocol to ensure fast and reliable communication of the host computer;
● It has a DC4-20mA analog output interface and is directly connected to the DCS system to monitor the field devices.
Function |
ARD2/ |
ALP300 |
ARD2F |
ARD3 |
ARD3T |
ARD3M |
|
Application |
Low voltage 0.4kv-1.14kv motor protection |
||||||
Protective function |
Start timeout |
√ |
|||||
Overload |
√ |
||||||
Underload |
√ |
||||||
Short circuit |
√ |
||||||
Blocking |
√ |
||||||
Stall |
√ |
||||||
Unbalance |
√ |
||||||
External Fault |
■ |
■ |
■ |
√ |
√ |
√ |
|
Insulation Fault |
|
|
|
|
|
√ |
|
OverVoltage |
|
√ |
■ |
■ |
■ |
√ |
|
Undervoltage |
|
√ |
■ |
■ |
■ |
√ |
|
Phase Failure |
√ |
√ |
√ |
√ |
√ |
√ |
|
Phase Sequence |
|
|
■ |
■ |
■ |
√ |
|
OverPower |
|
|
■ |
■ |
■ |
√ |
|
UnderPower |
|
|
■ |
■ |
■ |
√ |
|
tE time |
|
|
■ |
■ |
■ |
√ |
|
Loss of pressure (anti-shake) |
|
|
■ |
■ |
■ |
■ |
|
4-20mA input protection |
|
|
|
|
■ |
|
|
Ground |
√ |
||||||
Leakage |
■ |
||||||
Communication function |
ModbusRTU |
■ |
■ |
■ |
■ |
√ |
|
Double ModbusRTU |
|
|
■ |
■ |
■ |
√ |
|
Profibus DP |
|
|
■ |
■ |
■ |
■ |
|
Doubel Profibus DP |
|
|
|
|
|
■ |
|
Profinet |
|
|
|
|
|
■ |
|
Modbus TCP |
|
|
|
|
|
■ |
|
Switch input |
2 |
2 |
9 |
9 |
8 |
10 |
|
Relay output |
4 |
4 |
5 |
5 |
7 |
6 |
|
Start control |
|
|
■ |
√ |
√ |
√ |
|
4-20mA analog output |
■ |
||||||
Record |
■ |
|
■ |
■ |
√ |
■ |
|
Operational information record |
|
|
|
|
√ |
√ |
|
Logic function |
|
|
|
|
√ |
√ |
|
Parameter measurement |
Three-phase current |
√ |
|||||
Leakage current |
■ |
||||||
Three-phase voltage |
|
|
■ |
■ |
■ |
√ |
|
Power, power factor |
|
|
■ |
■ |
■ |
√ |
|
Frequency |
|
|
√ |
√ |
√ |
√ |
|
Electric energy |
|
|
■ |
■ |
■ |
√ |
|
PTC/NTC |
|
|
■ |
■ |
√ |
√ |
|
4-20mA input |
|
|
|
|
■ |
|
|
Temperature measurement module |
|
|
|
|
■ |
|
Photos on Site