● 380V±15%, 50Hz±2%
● Full response time ≤ 5ms
● 30kVA, 50kVA,75kVA or 100kVA
● RS485 (Modbus-RTU)or Ethernet (Modbus-TCP)
● Frozen data

  • product detail
  • parameter

General

Acrel power quality device is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement equipment (such as active filters, reactive power compensation equipment, etc.) to help improve user power quality and make users more economical, safe and reliable.


Acrel ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel in the entire power supply system, collect signals through transformers, and control the internal reactive power compensation module and active filter module according to the changes of load power factor and harmonic content in the power grid. power compensation and active filtering.


Static var generator is a new type of power electronics used to compensate for reactive power, harmonics, and regulation imbalances. Mainly used in hospitals, commercial plazas, manufacturing, data centers, charging piles, airports, photovoltaic and other industries.


Function

1) Flexible compensation method: Compensating for reactive power from the load, filter out harmonics within 5th, 7th, 9th, 11th, and 13th;

2) Ability of managing three-phase imbalance;

3) Linear compensation, Response time ≤ 5ms;

4) Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;

5) Adopt imported IGBT which has high power density and high reliability;

6) Using DSP digital control system for high speed detection and calculation;

7) With remote communication interface, real-time monitoring through PC;

8) Standard modular design which reduces lead times and increases reliability and maintainability.


Wiring



Dimension

Module


Wall mounted


Interface

Main interface


System information interface


Fault information interface


Parameter setting interface



Typical Connection

Wiring
3P3W or 3P4W
Voltage Input
380V
Frequency 50Hz
Reactive power compensation The target power factor can be set arbitrarily
Numbers of Harmonic Compensation 2-31st harmonics
Communication RS485 Modbus-RTU
Protection level IP30 customizable
Color RAL7035 customizable
Installation Indoor installation, fixed method and cable entry method are optional
Working temperature -10℃-+45℃
Working humidity 40℃: ≤50%RH,20℃: ≤90%RH
Altitude <2000m