● Primary current is connected through perforation. Easy installation, high safety.
● With Hall sensor, the max isolation measuring current 20A
● Voltage measurement range for Bus bar is up to DC1.5kV
● LED display, fit for checking and testing operation in wide-temperature or outside environment.
● With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box
● With RS485 Modbus RTU; More options of power supply
● Compatible with din rail installation and baseboard fixation installation, small dimension saving more box space.
General
AGF-M Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.
Specification
Wiring
Dimension
Power supply module size(Figure 1)
8-channel confluence acquisition module installation dimension(Figure 2)
4-channel confluence acquisition module installation dimension(Figure 3)
LCD display module installation dimension (Figure 4)
Installation
Connections of modules (Figure 5)
Installation schematic
Application
Item | AGF-M4T | AGF-M8T | AGF-M12T | AGF-M16T | AGF-M20T | AGF-M24T |
Input channels | 4 | 8 | 12 | 16 | 20 | 24 |
Rated current | DC 0~20A | |||||
Response time | 1s | |||||
Accuracy | 0.5 class | |||||
Temperature
coefficient
|
400ppm | |||||
RS485
communication
|
RS485/ModBus-RTU protocol,4800/9600/19200/38400bp | |||||
Additional function
|
||||||
Switch input | 3-way input(optocoupler or dry contact mode) | |||||
General technical parameters
|
||||||
Temperature/
Humidity
|
Working temperature: -35~+65℃, humidity95%, no condensation, no corrosion gas place*Display module, work temperature:-20~+70℃ |
|||||
Temperature
measurement
function
|
To measure the inner temperature of box (-20℃~100℃) | |||||
Altitude | ≤3000m | |||||
Insulation
resistance
|
≥100MΩ | |||||
Industrial
frequency
withstand
voltage
|
power/communication/switching input/cell voltage input--AC 2kV/1min
(When the auxiliary power supply is DC1500V, the withstand voltage between the
power supply, photocell input and other circuit is AC 2.7kV)
Current input/power、cell voltage 、communication、switching
state—AC3.5kV/1min
|
|||||
EMC
|
GB_T 17626.2-2006;
Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact
discharge 6kV.
|
|||||
GB_T 17626.4-2008;
Electrical fast transient immunity test grade 4, common mode 4kV, difference
mode 2kV
|
||||||
GB_T 17626.5-2008;
Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV
|
||||||
GB_T 17626.8-2006;
Power frequency magnetic field immunity test grade 4
|