● Rated Current: 10(60)A, 20(100)A
● Rated Voltage: AC220V
● RS485(MODBUS-RTU) Communication
● LCD Display; 35mm DIN Rail Installation
● Multi-tariff: 4 Tariff Rates (Spike, Peak, Valley and Flat kWh)
● Diverse Electricity Parameters Measurement
● kWh Class 1
General
ADL100 single phase din rail electric kWh energy meter is designed for single phase active energy measurementon low voltage system, at the same time it can measure the electrical parameters like voltage, current, power and so on. There is also RS485 communication can be chosen.
LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration.
This power meter has advantages ofsmaller volume, high precision, good EMC, easily installing etc, All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.
Product Selection
Specification
Technical Parameter |
ADL10-E |
ADL100-ET |
ADL100-ET/CT |
ADL200 |
|
Accuracy class |
Class 1 |
||||
Rated voltage |
220V |
||||
Current specification |
10(60)A |
20(100)A |
10(80)A |
||
Reference frequency |
50Hz |
||||
Starting Current |
Direct Connecting |
0.004lb |
|||
Power Consumption |
Voltage line |
<10VA |
|||
Current line |
<4VA |
||||
Electricity pulse output |
80ms±20ms |
||||
Clock error |
≤0.5s/D |
||||
Temperature range |
Normal working temperature:-25~55℃ storage temperature:-40~70℃ |
||||
Relative humidity |
≤95%(No condensation) |
||||
Outline (L*W*H) |
18*88*70mm |
36*88*70mm |
|||
Installation method |
TS35mm guide rail |
||||
Communication |
RS485 Modbus-RTU |
RS485 Modbus-RTU, Infrared |
RS485 Modbus-RTU |
Wiring
Wiring sample of current and voltage
Dimension
Installation
Typical Connection
Related Solution
Electric Energy Management System
Input voltage |
Rated voltage |
AC 220V |
|
Reference frequency |
50Hz |
||
Power consumption |
<10VA |
||
Input current |
Basic current |
10A, 20A |
|
Maximum current |
60A, 100A |
||
Starting current |
4‰Ib |
||
Consumption |
<4VA |
||
Measurement performance |
Accuracy of measuring |
kWh Class 1 |
|
Range of measuring |
000000.00~999999.99kWh |
||
Clock accuracy |
≤0.5s/d |
||
Active pulse |
Pulse width |
80±20ms |
|
Pulse constant |
1600imp/kWh |
||
Communication |
Interface |
RS485(A+、B-) |
|
Connection mode |
Shielded twisted pair conductors |
||
Protocol |
MOD BUS- RTU |
||
Dimensions (Length × Width × Height) |
88mm×36mm×70mm |
||
Temperature |
Work temperature |
-25℃~55℃ |
|
Storage Temperature |
-40℃~70℃ |
||
Relative humidity |
≤95%(No condensation) |
||
Altitude |
<2000m |