Multifunction Panel Energy Meter 0.5S APM800

● True RMS Measurements

● Unbalance & Phase Angles

● Demands and Multi-Tariff energy

● Max/Min Log with Timestamp

● Alarms and SOE Logs

● External Option module

  • product detail
  • parameter
  • FAQ

General

APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of thequality of power supply network.

This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording (SOE) module with T-Flash (TF) card, network communication module, can achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking function.


Specification

Type Function
APM800

Measure all electric parameters (class 0.5s), Neutralcurrent, unbalance, mean, extremum

2DI+2DO, RS485 Communication (Modbus-RTU protocol)

APM801

Measure all electric parameters (class 0.2s), Neutralcurrent, unbalance, mean, extremum

2DI+2DO, RS485 Communication (Modbus-RTU protocol)

APM810
Measure all electric parameters (class 0.5s), Neutralcurrent, unbalance, mean, extremum

2DI+2DO, 2-63rd harmonic, RS485 Communication (Modbus-RTU protocol)

APM830
Measure all electric parameters (class 0.2s), Neutralcurrent, unbalance, mean, extremum

2DI+2DO, odd、even harmonic and total harmonic, RS485 Communication (Modbus-RTU protocol)


LCD Display


Dimension

Meter and panel opening size(unit: mm(in))


Multiple meter installation (unit: mm(in))




Wiring

Wiring sample of current and voltage



Typical Connection


Related Solution

Electric Energy Management System


Connection
3 phase 3 wire, 3 phase 4 wire
Frequency
50Hz
Input Voltage
Rated Voltage
AC 100V, 110V, 400V, 690V
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
Input Current
Rated Voltage
AC 1A, 5A
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
Accuracy
Voltage, current and power
Class 0.5S(APM800, APM810)

Class 0.2S(APM801, APM830)

Active power
Reactive power
Class 2
Harmonic
1%(2-42nd), 2%(43-63rd)
Switch inputs
Passive contact inputs, built-in power supply
Relay outputs
Contact type: open contact in main part, changeover contact in module
Pulse capacity: 3A/AC250V, 3A/DC30V
Pulse output of energy
Output mode: Optocoupler pulse with open collector
Pulse constant: 4000(5A), 8000(1A) imp/kWh
Analog output
DC0-20mA, 4-20mA, 0-5V, 1-5V output, accuracy class 0.5%,
Load resistance≤500Ω
Analog input
DC0-20mA, 4-20mA, 0-5V, 1-5V input, accuracy class 0.5%,
Storage card
Standard capacity: 4G, TF card up to 32G capacity
Communication
RS485(Modbus-RTU), Profibus(Profibus-DP),
Ethernet(Modbus-TCP, HTTP, DHCP)
Auxiliary power supply
AC/DC 85~265V or AC/DC 115~415V
Electromagnetic compatibility
IEC 61000 standard(Level 4)
Environment
Operating temperature
-20~65℃
Storing temperature
-20~70℃
Humidity
≤95%(No condensation)
Altitude
≤2500m

Q: What’s the storage capacity, storage format and data storage interval of SD card?

A: The meter is equiped with standard 4G SD card while saving the data of electricalparameter, energy, event, SOE, alarm. Also, the setting of storage interval could bechanged. (1 min interval for electrical parameter and 1 hour interval for energy)


Q: How should I select the expanded modules of APM8xx?

A: Our users can select 3 of the optional modules at will even repeatly except forcommunication module. Also, the order of module installation could be random.


Q: The features of APM8xx?

A: Except for wave record and SD card storage function, 0.2S measuring accuracycan also be a option. Besides, APM8xx can serve as reverse display meter (whichmeans 3-phase electrical parameters measuring plus 8-channel reverse display)Also, users can measure the data through browser by using Ethernet auto WEB.


Q: As for the auxiliary power supply of APM8xx?

A: AC/DC 85~265V or 115~415V is both optional. Also, 380V line voltage can alsoserve as power supply.


Feedback form contact with us
Related Product
Rail Mounting Three Phase Energy Meter ADL400
Rail Mounting Three Phase Energy Meter ADL400
Quality Rail Mounting Three Phase Energy Meter ADL400 manufacturers & exporter - buy Rail Mounti...
Learn More
Din Rail Multi-Function Energy Meter ADL3000-E
Din Rail Multi-Function Energy Meter ADL3000-E
As the largest Din Rail Multi-Function Energy Meter ADL3000-E manufacturer in china, Acrel sales qua...
Learn More
Three Phase Prepaypaid Energy Meter ADL300-EY
Three Phase Prepaypaid Energy Meter ADL300-EY
Hot Three Phase Prepayment Meter,Prepaid Energy Meter - Acrel is the best Three Phase Prepayment Met...
Learn More
Product Catalog