● 0~1000V DC Measurement; Class 1; UL Certified
● 8 digitals LCD display; SOE record
● RS485 communication interface; Supports Modbus-RTU protocol
● Keypads HMI for Programming
● Dual Independent DC Circuits Monitoring
● Relay alarm output and digital input function
● Use matching with hall sensor (0-5V) or shunt (75mV)
● DC24V or DC48V power supply
● Set the ratio, alarm, and communication through the meter panel keys according to different requirements
● Event recording of switch (Modbus protocol), programming and event setting records, instantaneous and timing freeze function of data, maximum and minimum value recording function of voltage and current power
General
DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system. The actual use of the site,you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, computers to form a measurement and control system.
The meter have infrared communication interface and RS485 communication interface, and supports Modbus-RTU protocol and DLT645-97(07) protocol at the same time. The meter have relay alarm output and digital input function. It can set the ratio, alarm and communication through the meter panel keys according to different requirements. The meter have event recording of switch(Modbus protocol), programming and event setting records(645 protocol), instantaneous and timing freeze function of data(645 protocol), maximum and minimum value recording function of voltage and current power.
Specification
Type
|
Function
|
||
DJSF1352-RN
|
1. DC voltage, current, power measurement
2. Forward and reverse energy measurement
3. RS485 and infraredCommunication
4. Time sharing and multi rate energy measurement
5. SOE Sequence Of Event record
|
||
DJSF1352-RN/K | On the basis of DJSF1352-RN, add the switch function(2DI/2DO) | ||
DJSF1352-RN/D | On the basis of DJSF1352-RN, add the second channel of energy measurement | ||
DJSF1352-RN/KD | On the basis of DJSF1352-RN, add the second channel of energy measurement and switch function(2DI/2DO) |
Terminals and Wiring
Dimension
Typical Connection
Photo on Site
Function |
Display |
8-bit segment LCD screen (LCD) |
Communication Interface |
RS485, infrared |
|
Communication protocol |
Modbus-RTU, DL/T 645-2007 |
|
Switch |
Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC |
|
Switch input:2 dry contact inputs |
||
Pulse output |
A second pulse output, a energy pulse output |
|
See the SYS->PLUS display in the meter menu settings. For example: the meter displays 100, which is 100imp/kWH |
||
Power Supply
|
Voltage range |
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) |
Power consumption |
≤ 3W |
|
Power frequency withstand voltage |
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch input 2kV/1min |
|
Insulation resistance |
≥ 40M Ω |
|
Average barrier-free working hours |
≥50000h |