● Comprehensive energy storage monitoring and management functions, covering detailed information of energy storage system equipment (PCS, BMS, meters, fire protection, air conditioning, etc.) ;
● Achieve data acquisition, data processing, data storage, data query and analysis, visua monitoring, alarm management, and statistical reporting in advanced applications;
● Support energy dispatching, with control functions such as planned curves, peak shaving and valley filing, demand control, and backup power;
● Used for both energy storage integrated cabinets and energy storage containers, serving as a dedicated software system platform for equipment management.
● Application: commercial & enterprise, industrial zone, rural area (weak grid), island area, etc.
Solution Structure

Advantage
1) All System Management
Acrel-2000ES could integrate with ESS and manage all sub system including PCS, BMS, air conditioner, fire protection, energy monitoring and etc.

2) Peak-Valley Arbitrage
By using the energy management and control plan of Acrel-2000ES, we could realize peak shaving &valley filling energy usage strategy for peak-valley arbitrage. Benefit of peak-valley arbitrage could be check in Acrel-2000ES energy magament system.

3) Power Demand Control
Acrel-2000ES could set a power demand threshold and manage all the power system in micro-grids so that the overall loads power demand won't exceed this limitation value. No extra fine happend due to exceeding the power demand.

4) Back-up Power Source
Acrel-2000ES EMS system could set the plan for back-up power source to prevent the influence of unpredicatable power outage.

Software Overview
1) System Homepage
Homepage include a general view of PCS & BMS working status, charging & discharging energy, income gain by optimized power control, SOC curve, system power curve, air conditioning/fan/fire/ups protection working status and etc.
2) Optimized Power Control
Acrel-2000ES could set various charging&discharging control plan to realize optimized power operation for saving your money and make profit. Such as peak-valley arbitrage, max demand control, zero export to grids control, back-up energy for power outage prevention and etc.
3) PCS Management
Providing a general management and monitoring for PCS including grid-connected & off-grid running mode switch, PCS on/off control current & voltage & power monitoring and alarm threshold setting, fault alarm status, battery SOC & voltage & current monitoring & alarm and etc.
4) BMS Management
General monitoring for BMS including charger & discharger stutus, battery SOC & SOH, battery voltage & current & temperature monitoring and threshold exceeding alarm.
5) Diesel Generator Management
General monitoring for diesel generator including common electricity and engine status monitoring, diesel generator fault alarm status and etc.
6) Energy Metering
By connecting to energy meter for monitoring all common electricity parameter and charging & discharging energy of overall ESS system.
7) Dehumidifier Monitoring
General monitoring for dehumidifier including working ambient tempertaure & humidity, communications status.
8) Fire Monitoring
General monitoring for fire protection system in ESS. By connecting I/O module to related sensor for monitoring the fire equipment working status.
|
Product Picture |
Name & Model |
Technical Description |
|
|
Acrel-2000ES Software & Industrial Tablet PC PC & Software |
Data collection and monitoring of internal equipment, consisting of communication management machine, industrial tablet PC, serial server, remote signaling module, and related communication accessories. Data collection, upload, and forwarding to server and coordinated control devices. Strategy control: planned curves, demand control, peak shaving and valley filling, backup power, etc. |
|
ANET series IoT gateway utilizes an embedded hardware computing platform and features multiple downstream communication interfaces and multiple upstream network interfaces. It is designed to aggregate and organize communication data from all intelligent monitoring/protection devices within a target area and upload it in real-time to the master station system. This setup completes the functions of remote signaling and remote measurement for energy data collection. |
||
|
ADL3000-E Series 3 Phase Din Rail Multifunction Energy Meter |
ADL3000-E is an intelligent electric meter specifically designed for power supply systems, industrial and mining enterprises, and utility companies. It is used to calculate electricity consumption and manage electrical demand. Key features include high accuracy, compact size, and easy installation. The device integrates measurement of all electrical parameters and comprehensive power metering management, providing data for the past 12 months. It can check the content of up to 31 harmonics and total harmonic distortion. Remote communication and control are enabled through digital inputs and relay outputs, and it also features alarm outputs. ADL3000-E is suitable for various control systems, SCADA systems, and energy management systems. All instruments comply with the relevant technical requirements of IEC62053-21 and IEC62053-22 standards for power meters. |
|
|
Measures voltage, current, power, and bidirectional energy in DC systems; Optional dual channel DC metering; Equipped with infrared communication interface and RS-485 communication interface, supporting both Modbus RTU protocol; Can be equipped with relay alarm output and switch input functions. |
||
|
Suitable for multi-channel temperature measurement and control, supports up to 8-channel PT100 temperature measurement, with optional channel shielding; each channel temperature measurement corresponds to 2-stage alarm, relay output can set alarm direction and value. |
||
|
[1] Feedback the on/off status of each device via I/O, and send the related data to the upstream gateway and system [2] Read fire protection I/O signals and forward them to the upper layer (shutdown, event reporting, etc.) [3] Collect water immersion sensor information and forward it to the upper layer (water immersion signal event reporting) [4] Read access control sensor information and forward it to the upper layer (access control event reporting) |